Part Details for S90R11ABD1-120 by TE Connectivity
Results Overview of S90R11ABD1-120 by TE Connectivity
- Distributor Offerings: (2 listings)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
S90R11ABD1-120 Information
S90R11ABD1-120 by TE Connectivity is a Power/Signal Relay.
Power/Signal Relays are under the broader part category of Relays.
A relay is an electromechanical switch that uses an electrical signal to open or close circuits, protecting systems from overcurrents or voltage surges. They are used in a variety of applications, including lighting control, telecommunication, automotive systems, and power protection. Read more about Relays on our Relays part category page.
Price & Stock for S90R11ABD1-120
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
DISTI #
48M8205
|
Newark | S90R11Abd1-120=Solenoids |Potter&brumfield Te Connectivity S90R11ABD1-120 RoHS: Not Compliant Min Qty: 1 Package Multiple: 1 Date Code: 0 Container: Bulk | 0 |
|
Buy Now | |
DISTI #
000000000000049005
|
Sager | Solenoids & Actuators DPDT 20A QC 120VAC | 0 |
|
Buy Now |
Part Details for S90R11ABD1-120
S90R11ABD1-120 CAD Models
S90R11ABD1-120 Part Data Attributes
|
S90R11ABD1-120
TE Connectivity
Buy Now
Datasheet
|
Compare Parts:
S90R11ABD1-120
TE Connectivity
POWER/SIGNAL RELAY, DPDT, LATCHED, 9000mW (COIL), 20A (CONTACT), SOCKET MOUNT, ROHS COMPLIANT
|
Rohs Code | Yes | |
Part Life Cycle Code | Obsolete | |
Ihs Manufacturer | TE CONNECTIVITY LTD | |
Package Description | ROHS COMPLIANT | |
Reach Compliance Code | compliant | |
ECCN Code | EAR99 | |
Samacsys Manufacturer | TE Connectivity | |
Additional Feature | COIL OPERATE VOLTAGE(AC): 102 V | |
Body Breadth | 50.8 mm | |
Body Height | 61.5 mm | |
Body Length or Diameter | 68.6 mm | |
Coil Current(AC)-Max | 0.075 A | |
Coil Power | 9000 mW | |
Coil Resistance | 260 Ω | |
Coil Voltage(AC)-Max | 120 V | |
Coil/Input Supply Type | AC | |
Contact (AC) Max Rating R Load | 20A@120VAC | |
Contact Current(AC)-Max | 20 A | |
Contact Current(DC)-Max | 20 A | |
Contact Voltage(AC)-Max | 120 V | |
Contact/Output Supply Type | AC/DC | |
Electrical Life | 10000 Cycle(s) | |
Mounting Feature | SOCKET MOUNT | |
Operating Temperature-Max | 60 °C | |
Operating Temperature-Min | -10 °C | |
Physical Dimension | 68.6mm x 50.8mm x 61.5mm | |
Reference Standard | CSA; UL | |
Relay Action | LATCHED | |
Relay Function | DPDT | |
Relay Type | POWER/SIGNAL RELAY | |
Surface Mount | NO | |
Termination Type | SNAP ON |
S90R11ABD1-120 Frequently Asked Questions (FAQ)
-
The recommended torque for the screw terminals is 0.5 Nm to 1.5 Nm, depending on the wire size and type. It's essential to follow the recommended torque to ensure reliable connections and prevent damage to the terminals.
-
Yes, the S90R11ABD1-120 is designed to withstand high-vibration environments. It meets the IEC 61373 Cat 2 standard for vibration resistance, making it suitable for use in applications such as rail, industrial, and automotive.
-
The S90R11ABD1-120 has a IP67 rating, which means it is protected against dust and water ingress. However, it's essential to ensure that the connector is properly sealed and mated to maintain its environmental rating. Additionally, the connector's materials and coatings should be suitable for the specific outdoor environment.
-
While the datasheet specifies a wire size range of 0.5 mm² to 2.5 mm², it's possible to use the connector with smaller or larger wire sizes. However, this may require additional processing or specialized tools, and it's recommended to consult with TE Connectivity or a qualified engineer to ensure reliable connections.
-
The S90R11ABD1-120 has an operating temperature range of -40°C to 125°C, making it suitable for use in a wide range of applications. However, it's essential to consider the temperature rating of the specific wire and cable used with the connector.