Part Details for MAX4080TAUA+ by Maxim Integrated Products
Results Overview of MAX4080TAUA+ by Maxim Integrated Products
- Distributor Offerings: (3 listings)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
MAX4080TAUA+ Information
MAX4080TAUA+ by Maxim Integrated Products is an Operational Amplifier.
Operational Amplifiers are under the broader part category of Amplifier Circuits.
Amplifier circuits use external power to increase the amplitude of an input signal. They can be used to perform linear amplifications or logarithmic functions. Read more about Amplifier Circuits on our Amplifier Circuits part category page.
Price & Stock for MAX4080TAUA+
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
DISTI #
78Y4931
|
Newark | Currentsense Amp, 250Khz, -40To125Deg C, Current Sense Amplifier Type:High Side, Gain Bandwidth Product:250Khz, Ic Case/Package:Μmax, No. Of Pins:8Pins, Operating Temperature Min:-40°C, Operating Temperature Max:125°C, Cmrr:124Db Rohs Compliant: Yes |Maxim Integrated/analog Devices MAX4080TAUA+ RoHS: Compliant Min Qty: 1 Package Multiple: 1 Date Code: 1 Container: Bulk | 8 |
|
$0.6190 | Buy Now |
DISTI #
MAX4080TAUA+-ND
|
DigiKey | IC CURRENT SENSE 1 CIRCUIT 8UMAX Min Qty: 1 Lead time: 10 Weeks Container: Tube |
1330 In Stock |
|
$2.1753 / $4.0000 | Buy Now |
|
Vyrian | Amplifiers | 225 |
|
RFQ |
Part Details for MAX4080TAUA+
MAX4080TAUA+ CAD Models
MAX4080TAUA+ Part Data Attributes
|
MAX4080TAUA+
Maxim Integrated Products
Buy Now
Datasheet
|
Compare Parts:
MAX4080TAUA+
Maxim Integrated Products
Operational Amplifier, 1 Func, 1200uV Offset-Max, BIPolar, PDSO8, MICROMAX-8
|
Pbfree Code | Yes | |
Rohs Code | Yes | |
Part Life Cycle Code | Transferred | |
Ihs Manufacturer | MAXIM INTEGRATED PRODUCTS INC | |
Part Package Code | SOIC | |
Pin Count | 8 | |
Reach Compliance Code | compliant | |
ECCN Code | EAR99 | |
HTS Code | 8542.33.00.01 | |
Amplifier Type | OPERATIONAL AMPLIFIER | |
Average Bias Current-Max (IIB) | 12 µA | |
Common-mode Reject Ratio-Nom | 124 dB | |
Input Offset Voltage-Max | 1200 µV | |
JESD-30 Code | S-PDSO-G8 | |
JESD-609 Code | e3 | |
Length | 3 mm | |
Moisture Sensitivity Level | 1 | |
Number of Functions | 1 | |
Number of Terminals | 8 | |
Operating Temperature-Max | 125 °C | |
Operating Temperature-Min | -40 °C | |
Package Body Material | PLASTIC/EPOXY | |
Package Code | SOP | |
Package Shape | SQUARE | |
Package Style | SMALL OUTLINE | |
Peak Reflow Temperature (Cel) | 260 | |
Qualification Status | Not Qualified | |
Seated Height-Max | 1.1 mm | |
Supply Voltage Limit-Max | 80 V | |
Supply Voltage-Nom (Vsup) | 48 V | |
Surface Mount | YES | |
Technology | BIPOLAR | |
Temperature Grade | AUTOMOTIVE | |
Terminal Finish | MATTE TIN | |
Terminal Form | GULL WING | |
Terminal Pitch | 0.65 mm | |
Terminal Position | DUAL | |
Time@Peak Reflow Temperature-Max (s) | 30 | |
Unity Gain BW-Nom | 250 | |
Width | 3 mm |
MAX4080TAUA+ Frequently Asked Questions (FAQ)
-
A good PCB layout for the MAX4080TAUA+ involves keeping the analog and digital grounds separate, using a solid ground plane, and placing the device close to the current sense resistor. Additionally, it's recommended to use a Kelvin connection to the sense resistor to minimize parasitic inductance and resistance.
-
Calibration of the MAX4080TAUA+ involves applying a known current to the sense resistor and adjusting the gain and offset of the device to match the expected output voltage. This can be done using an external calibration circuit or through software calibration using the device's internal registers.
-
The MAX4080TAUA+ can measure currents up to ±3A, and it has an overcurrent detection feature that can detect currents up to ±6A. In the event of an overcurrent condition, the device will output a fault signal and can be configured to latch off the power supply to protect the system.
-
The MAX4080TAUA+ has a high common-mode rejection ratio (CMRR) and can handle common-mode voltages up to ±12V. The recommended common-mode voltage range is ±5V to ensure accurate measurements and to prevent damage to the device.
-
The MAX4080TAUA+ has a typical power consumption of 1.5mA. To reduce power consumption, you can use the device's shutdown mode, which reduces power consumption to 1μA. Additionally, you can use a lower supply voltage and optimize the device's bandwidth to reduce power consumption.