Part Details for SRD-SH-112DM by Sanyou Relays
Results Overview of SRD-SH-112DM by Sanyou Relays
- Distributor Offerings: (2 listings)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
SRD-SH-112DM Information
SRD-SH-112DM by Sanyou Relays is a Power/Signal Relay.
Power/Signal Relays are under the broader part category of Relays.
A relay is an electromechanical switch that uses an electrical signal to open or close circuits, protecting systems from overcurrents or voltage surges. They are used in a variety of applications, including lighting control, telecommunication, automotive systems, and power protection. Read more about Relays on our Relays part category page.
Available Datasheets
Part # | Manufacturer | Description | Datasheet |
---|---|---|---|
CC1000PWR | Texas Instruments | Single Chip Ultra Low Power RF Transceiver for 315/433/868/915 MHz SRD Band 28-TSSOP -40 to 85 | |
CC1050PWR | Texas Instruments | Single Chip Ultra Low Power RF Transmitter for the 315/433/868/915 MHz SRD Band 24-TSSOP -40 to 85 | |
CC1000PW | Texas Instruments | Single Chip Ultra Low Power RF Transceiver for 315/433/868/915 MHz SRD Band 28-TSSOP -40 to 85 |
Price & Stock for SRD-SH-112DM
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
|
Bristol Electronics | 13500 |
|
RFQ | ||
DISTI #
SRD-SH-112DM
|
TME | Relay: electromagnetic, SPST-NO, Ucoil: 12VDC, Icontacts max: 10A Min Qty: 1 | 1954 |
|
$0.2930 / $0.5990 | Buy Now |
Part Details for SRD-SH-112DM
SRD-SH-112DM CAD Models
SRD-SH-112DM Part Data Attributes
|
SRD-SH-112DM
Sanyou Relays
Buy Now
Datasheet
|
Compare Parts:
SRD-SH-112DM
Sanyou Relays
Power/Signal Relay, SPST, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), DC Input, AC Output, Through Hole-Straight Mount
|
Part Life Cycle Code | Contact Manufacturer | |
Ihs Manufacturer | SANYOU ELECTRICAL APPLIANCES 2011 INC | |
Reach Compliance Code | unknown | |
ECCN Code | EAR99 | |
Body Breadth | 15.4 mm | |
Body Height | 15.5 mm | |
Body Length or Diameter | 19.6 mm | |
Coil Current(DC)-Max | 0.03 A | |
Coil Operate Voltage(DC) | 9 V | |
Coil Power | 360 mW | |
Coil Release Voltage(DC) | 0.6 V | |
Coil Resistance | 400 Ω | |
Coil Voltage(DC)-Max | 12 V | |
Coil/Input Supply Type | DC | |
Contact (AC) Max Rating R Load | 15A@277VAC | |
Contact Current(AC)-Max | 15 A | |
Contact Voltage(AC)-Max | 277 V | |
Contact/Output Supply Type | AC | |
Electrical Life | 100000 Cycle(s) | |
End Contact Material | Silver Alloy | |
Input Switching Control Type | Random | |
Mounting Feature | THROUGH HOLE-STRAIGHT | |
Number of Terminals | 4 | |
Operate Time | 8 ms | |
Operating Temperature-Max | 105 °C | |
Operating Temperature-Min | -40 °C | |
Physical Dimension | 19.6mm x 15.4mm x 15.5mm | |
Reference Standard | CQC; CUL; IEC; TUV; UL; VDE | |
Relay Action | MOMENTARY | |
Relay Form | 1 FORM A | |
Relay Function | SPST | |
Relay Type | POWER/SIGNAL RELAY | |
Release Time | 5 ms | |
Sealing | EXPLOSION PROOF; WATER PROOF | |
Surface Mount | NO | |
Terminal Length | 0.003500127000254001 inch | |
Termination Type | SOLDER |
SRD-SH-112DM Frequently Asked Questions (FAQ)
-
The recommended PCB layout and land pattern for SRD-SH-112DM can be found in the Sanyou Relays' application note or by contacting their technical support. It's essential to follow the recommended layout to ensure proper relay operation and to prevent overheating or electrical noise issues.
-
To ensure proper relay operation, it's essential to follow the recommended drive circuit and control voltage specified in the datasheet. Additionally, consider using a buffer circuit or a dedicated relay driver IC to ensure the relay is driven correctly and to prevent back-EMF damage.
-
The maximum switching frequency for SRD-SH-112DM is not explicitly stated in the datasheet, but it's typically limited by the relay's mechanical switching time and the application's requirements. As a general rule, it's recommended to limit the switching frequency to 1-2 Hz to ensure reliable operation and to prevent excessive wear on the relay's contacts.
-
While the SRD-SH-112DM has an operating temperature range of -40°C to 85°C, it's essential to consider the relay's derating curve and the application's specific requirements. In high-temperature environments, the relay's performance and lifespan may be affected, and additional cooling measures or relay selection may be necessary.
-
The SRD-SH-112DM requires a specific coil voltage and current to operate correctly. Ensure that the power supply and drive circuit can provide the required voltage and current, and consider using a voltage regulator or current limiter to prevent overheating or damage to the relay.