Part Details for HSCDJJN001NDAA5 by Honeywell Sensing and Control
Results Overview of HSCDJJN001NDAA5 by Honeywell Sensing and Control
- Distributor Offerings: (4 listings)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
HSCDJJN001NDAA5 Information
HSCDJJN001NDAA5 by Honeywell Sensing and Control is a Pressure Sensor.
Pressure Sensors are under the broader part category of Sensors/Transducers.
Sensors and transducers detect and measure physical quantities like temperature, pressure, and force, converting them into electrical signals for various applications. Read more about Sensors/Transducers on our Sensors/Transducers part category page.
Price & Stock for HSCDJJN001NDAA5
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
DISTI #
44Y5901
|
Newark | Trustability Pressure Sensor |Honeywell HSCDJJN001NDAA5 RoHS: Not Compliant Min Qty: 100 Package Multiple: 1 Date Code: 0 Container: Bulk | 0 |
|
$49.9100 | Buy Now |
DISTI #
480-HSCDJJN001NDAA5-ND
|
DigiKey | TRUSTABILITY PRESSURE SENSOR Min Qty: 100 Lead time: 12 Weeks Container: Bulk | Temporarily Out of Stock |
|
$40.7400 | Buy Now |
DISTI #
HSCDJJN001NDAA5
|
TME | Sensor: pressure, -2.5÷2.5mbar, differential, OUT: analogue, THT Min Qty: 100 | 0 |
|
$107.4000 | RFQ |
|
Master Electronics | TruStability® Board Mount Pressure Sensor Compensated/Amplified: HSC Series, High Accuracy, ± 1% Total Error Band, DIP, Dual Radial Barbless Ports, Same Side, 1 inH₂O Differential, Analog Output, 10% to 90% Vdd, 5.0 Vdc Supply, Dry Gases Only, No Diagnostics RoHS: Compliant | 0 |
|
$42.1400 / $115.4300 | Buy Now |
Part Details for HSCDJJN001NDAA5
HSCDJJN001NDAA5 CAD Models
HSCDJJN001NDAA5 Part Data Attributes
|
HSCDJJN001NDAA5
Honeywell Sensing and Control
Buy Now
Datasheet
|
Compare Parts:
HSCDJJN001NDAA5
Honeywell Sensing and Control
Peizoresistive Sensor,
|
Rohs Code | Yes | |
Part Life Cycle Code | Active | |
Ihs Manufacturer | HONEYWELL SENSING AND CONTROL | |
Package Description | DIP-6 | |
Reach Compliance Code | compliant | |
Accuracy-Max (%) | 0.25% | |
Additional Feature | Port Diameter = 2.34 MM and Port Height = 6.75 MM | |
Body Breadth | 9.91 mm | |
Body Height | 6.51 mm | |
Body Length or Diameter | 13.3 mm | |
Housing | CERAMIC | |
Mounting Feature | THROUGH HOLE MOUNT | |
Operating Current-Max | 3.5 mA | |
Operating Temperature-Max | 85 °C | |
Operating Temperature-Min | -20 °C | |
Output Range | 0.5-4.5V | |
Output Type | ANALOG OUTPUT | |
Package Shape/Style | RECTANGULAR | |
Port Type | STRAIGHT | |
Pressure Range-Max | 0.03 Psi | |
Pressure Range-Min | -0.03 Psi | |
Pressure Sensing Mode | DIFFERENTIAL | |
Response Time | 1000 µs | |
Sensors/Transducers Type | PRESSURE SENSOR,PIEZORESISTIVE | |
Supply Voltage-Max | 5.05 V | |
Supply Voltage-Min | 4.95 V | |
Surface Mount | NO | |
Termination Type | SOLDER |
HSCDJJN001NDAA5 Frequently Asked Questions (FAQ)
-
The recommended power-up sequence is to apply Vcc first, followed by Vdd, and then the input signal. This ensures proper initialization of the internal circuitry and prevents any potential damage to the device.
-
To handle the output signal in a noisy environment, it is recommended to use a low-pass filter or a shielded cable to minimize electromagnetic interference (EMI). Additionally, consider using a signal conditioning circuit to amplify and filter the output signal.
-
The maximum operating temperature range for the HSCDJJN001NDAA5 is -40°C to 150°C. However, it's recommended to operate the device within the specified temperature range for optimal performance and accuracy.
-
Yes, the HSCDJJN001NDAA5 is designed to operate in high-vibration environments. However, it's recommended to follow proper mounting and installation procedures to ensure the device is securely fastened and protected from mechanical stress.
-
The recommended calibration procedure involves applying a known input signal to the device and adjusting the output signal to match the expected value. It's recommended to follow the calibration procedure outlined in the datasheet or consult with a qualified engineer or technician.