Part Details for HSCDANT100PGSA3 by Honeywell Sensing and Control
Results Overview of HSCDANT100PGSA3 by Honeywell Sensing and Control
- Distributor Offerings: (9 listings)
- Number of FFF Equivalents: (0 replacements)
- CAD Models: (Request Part)
- Number of Functional Equivalents: (0 options)
- Part Data Attributes: (Available)
- Reference Designs: (Not Available)
Tip: Data for a part may vary between manufacturers. You can filter for manufacturers on the top of the page next to the part image and part number.
HSCDANT100PGSA3 Information
HSCDANT100PGSA3 by Honeywell Sensing and Control is a Pressure Sensor.
Pressure Sensors are under the broader part category of Sensors/Transducers.
Sensors and transducers detect and measure physical quantities like temperature, pressure, and force, converting them into electrical signals for various applications. Read more about Sensors/Transducers on our Sensors/Transducers part category page.
Price & Stock for HSCDANT100PGSA3
Part # | Distributor | Description | Stock | Price | Buy | |
---|---|---|---|---|---|---|
DISTI #
70AC4744
|
Newark | Trustability Pressure Sensor |Honeywell HSCDANT100PGSA3 RoHS: Not Compliant Min Qty: 100 Package Multiple: 1 Date Code: 0 Container: Bulk | 0 |
|
$51.9000 | Buy Now |
DISTI #
480-HSCDANT100PGSA3-ND
|
DigiKey | HSCDANT100PGSA3 Min Qty: 100 Lead time: 12 Weeks Container: Bulk | Temporarily Out of Stock |
|
$31.1400 | Buy Now |
DISTI #
785-HSCDANT100PGSA3
|
Mouser Electronics | Board Mount Pressure Sensors DIP,Single Ax Barbed Gage, 3.3V RoHS: Compliant | 0 |
|
$31.1400 | Order Now |
DISTI #
V36:1790_18635722
|
Arrow Electronics | Board Mount Pressure Sensor 0psi to 100psi Gage Medical 8-Pin DIP Module RoHS: Compliant Min Qty: 1 Package Multiple: 1 Lead time: 8 Weeks Date Code: 2322 | Americas - 27 |
|
$59.9840 | Buy Now |
DISTI #
84417495
|
Verical | Board Mount Pressure Sensor 0psi to 100psi Gage Medical 8-Pin DIP Module RoHS: Compliant Min Qty: 2 Package Multiple: 1 | Americas - 50 |
|
$35.0700 / $37.1400 | Buy Now |
DISTI #
69099818
|
Verical | Board Mount Pressure Sensor 0psi to 100psi Gage Medical 8-Pin DIP Module RoHS: Compliant Min Qty: 1 Package Multiple: 1 Date Code: 2322 | Americas - 27 |
|
$62.1653 | Buy Now |
DISTI #
HSCDANT100PGSA3
|
TME | Sensor: pressure, 0÷100psi, gage, OUT: SPI, Usup: 3÷3.6VDC,3.3VDC Min Qty: 100 | 0 |
|
$78.4200 | RFQ |
DISTI #
HSCDANT100PGSA3
|
IBS Electronics | BOARD MOUNT PRESSURE SENSORS DIP SINGLE AX BARBED GAGE 3.3V Min Qty: 4 Package Multiple: 1 | 50 |
|
$35.0750 / $37.1375 | Buy Now |
|
Master Electronics | RoHS: Compliant |
50 Partner Stock |
|
$32.8500 / $94.1700 | Buy Now |
Part Details for HSCDANT100PGSA3
HSCDANT100PGSA3 CAD Models
HSCDANT100PGSA3 Part Data Attributes
|
HSCDANT100PGSA3
Honeywell Sensing and Control
Buy Now
Datasheet
|
Compare Parts:
HSCDANT100PGSA3
Honeywell Sensing and Control
Peizoresistive Sensor, Gage, 0Psi Min, 100Psi Max, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, DIP-8
|
Rohs Code | Yes | |
Part Life Cycle Code | Active | |
Ihs Manufacturer | HONEYWELL SENSING AND CONTROL | |
Package Description | DIP-6 | |
Reach Compliance Code | compliant | |
Accuracy-Max (%) | 0.25% | |
Additional Feature | Port Diameter = 4.93 MM and Port Height = 7.95 MM | |
Body Breadth | 10 mm | |
Body Height | 5.8 mm | |
Body Length or Diameter | 13.3 mm | |
Housing | CERAMIC | |
Mounting Feature | THROUGH HOLE MOUNT | |
Number of Bits | 12 | |
Operating Current-Max | 3.9 mA | |
Operating Temperature-Max | 85 °C | |
Operating Temperature-Min | -20 °C | |
Output Interface Type | SPI | |
Output Range | 0.33-2.97V | |
Output Type | DIGITAL VOLTAGE | |
Package Shape/Style | RECTANGULAR | |
Port Type | BARBED | |
Pressure Range-Max | 100 Psi | |
Pressure Range-Min | ||
Pressure Sensing Mode | GAGE | |
Response Time | 460 µs | |
Sensors/Transducers Type | PRESSURE SENSOR,PIEZORESISTIVE | |
Supply Voltage-Max | 3.6 V | |
Supply Voltage-Min | 3 V | |
Surface Mount | NO | |
Termination Type | SOLDER |
HSCDANT100PGSA3 Frequently Asked Questions (FAQ)
-
The recommended power-up sequence is to apply Vcc first, followed by Vdd, and then the input signal. This sequence helps prevent latch-up and ensures proper operation.
-
To minimize the effects of noise, use a low-pass filter or a shielded cable to connect the sensor to the microcontroller or other downstream devices. Additionally, consider using a differential amplifier to amplify the signal and improve noise immunity.
-
The sensor is designed to withstand vibrations up to 10g peak acceleration, 10-2000 Hz frequency range. Exceeding this limit may affect the sensor's accuracy and reliability.
-
The sensor is rated for operation up to 125°C (257°F). However, the accuracy and reliability may degrade above 100°C (212°F). If high-temperature operation is required, consider using a thermally compensated version of the sensor or implementing additional temperature compensation measures.
-
Calibration is not typically required for the HSCDANT100PGSA3, as it is a pre-calibrated sensor. However, if you need to adjust the sensor's output for a specific application, you can use the built-in offset and gain adjustments. Refer to the datasheet for specific calibration procedures.